ACL Staticide   >> Static Detection Meters
   
 

ACL 300B Precision Electrostatic Locator Meter
Measures static charges instantly from 0 - 30,000 volts reliably.
Most widely used electrostatic locator
Designed for close and repetitive readings
Uses standard 9 volt battery with battery test feature
Low drift, repeatability + / - 1 %


ACL 350 Digital Static Locator
Non-contact meter that indicates electrostatic field voltage & polarity on charged particles
Power on / hold & zero button
Auto shut off after 90 seconds
Easy to read 3 - 1/2 digit LCD display automatically updates three times per second
Measures voltages in many applications ( packaging, production aids & raw materials
Range 0 - 80,000 volts


ACL 380 Surface Resistivity Meter
Assurance Check for Packaging & Assembly Lines
Easy to use, the ACL 380 handheld surface resistivity meter shows values through an LED scale that is coded with colors to signify conductive, dissipative, and insulative. There is also a colored "warning" stage to signal to the auditor that the material is at the higher end of the dissipative range and is close to being out of specification. Half decades indicate where the measurement value falls within the decade giving a closer indication to actual value.
Four color LED display segments (including warning stage)
Half decades for greater accuracy
Rails: tin copper wire
Dimensions: 2.8" x 5.1" x 1.4"
Conforms to ASTM D257
Includes calibration certificate


ACL 395 Surface Resistivity Meter
More Economical Than Megohmmeters
The ACL 395 handheld meter features sophisticated circuitry that allows for the same advantages as megohmmeters, but at an economical price. Utilizing color-coded zones, the LED scale is easy to read and evaluate. Half decades indicate where the measurement value falls within the decade giving a closer indication to actual value. Unlike other pocket-sized meters, the ACL 395 features rubber rails which provide the best possible contact..
Four color LED display segments (including warning stage)
Half decades for greater accuracy
Rails: conductive rubber
vDimensions: 2.8" x 5.1" x 1.4"
Conforms to ASTM D257
Includes calibration certificate


ACL 450 Ionised Environment Electrostatic Locator
Ideal for Electronic Manufacturing Operations
The ACL 450 allows for drift-free accuracy even in ionized environments. This hand-held field meter produces consistent and accurate measurements and can be used to perform static surveys and evaluate charge accumulation in electronic manufacturing and in industrial operations such as converting, printing, packaging, and plastics processing. Its super sensitive electrode and stabilizing circuitry make this the perfect meter to use in electronic component production and assembly areas, textiles, packaging, engineering labs, and printing.
Digital 3-1/2 digit LCD
Uses standard 9-volt
Unique pulsing beam for accurate distance measurements at 1"
Test range at 1" away from target: 0 - 19.99 kV
Test range at 4" away from target: 0 - 40 kV
Indicates polarity
Quick zeroing button
Measurement "HOLD" button
Optional charged-plate adapter available (Model 282CPS) Includes calibration certificate   traceable to NIST


ACL 600 Stati-Check Meter
A unique visual method is provided by the ACL 600 to detect how much static charge a person is carrying.
Can be easily wall mounted outside of a sensitive area to provide voltage readings
   on persons entering
Provides a repetitive read for operators already present in the area
Effective in detecting the difference in static potential between two people
Determines the effectiveness of wrist straps, coil, cords, bonding plugs, custom
   floors, spray coating, garments & chairs


ACL 680 Personal Wrist and Footwear Tester
Simple Meter Grounding Tester
The 680 Wrist and Footwear Grounding Tester is a good alternative for companies seeking a personal auditing station but do not need to save data. This simple meter will indicate resistance with a "high", "low" or "pass" signal when testing wrist and heel straps separately. Suitable testing station for small companies using stricter ESDA guidelines which require grounding strap system to test lower than 3.5 x 107 ohms.
Test wrist and feet one at a time
Limits are set to 35m
Optional circuit relay for security doors
Includes calibration certificate


ACL 750 Combo Tester Kit with Software
Used to monitor & analyse wrist straps & heel straps grounders simultaneously
Easy to use software; stores employee test results in computer
Conforms to ISO - 9000 requirements
Measures electrical resistance of wrist straps / heel grounders from 500 kilohms
   to 100 megohms
Software can store reports up to 2,500 employees
Installed on any Windows 95 & 98 or 3.1 compatible PC ( except Windows 3.1 for
   workgroups )
Includes meter, Windows based software and heavy duty foot stand


ACL780 Economy Combo Tester
The ACL 780 Economy Combo-Tester measures electrical resistance of wrist straps and heel grounders simultaneously and individually. This is a good alternative for companies seeking a personal auditing station but do not need to save data. Adjustable limits add versatility for ESD managers that may need to modify verification plans.
Simultaneous testing for wrist and feet
Adjustable limits from 500k and 750k for low setting and 2M to 100M ohms high setting
Optional circuit relay for security doors
Includes calibration certificate traceable to NIST


ACL 800 Megohmmeter

Designed to measures temperature, humidity & electrical resistance / resistivity
Compact, lightweight & portable
Uses both external & internal test probes to measure resistivity / resistance between two points, and resistance to ground according to EOS/ESD Association Standards, - S4.1 , S7.1 , S11.11 and European Standard CECC - EN 1000 / 15

 
 